The SimVT tool can can be run directly from the JavaScript menu in T/HIS (). This is useful if you want to use the tool without loading Ansys LS-DYNA results into T/HIS.

Steps in T/HIS
In this example we will correlate CSV data vs. ISO-MME data to demonstrate using both types of data.
- Open T/HIS
- Select
- On the Correlation Setup window click Import ISO-MME or CSV… and select an ISO-MME index file (the extension should be ".mme", “.mmi”, “.chn” or “.iso”).
- On the Correlation Setup window click Import ISO-MME or CSV… and select a CSV data file.
- On the Correlation Setup window, select T1 as the "Reference test" and select as the simulation.
- Select the method you want to use for correlating.
- Add/remove any channel matching rules that you require to match T1 channels to T2.
- Select the channels you want to correlate in the channel list (or select all of them by clicking on the ).
- Click . The setup window will disappear, and it will be replaced by three windows:
- Progress window
- Correlation Table
- Plotting Controls
- Once the progress window has disappeared you can inspect the results on the Correlation Table and plot the correlation graphs by using the buttons on the table.
- You can also perform corrective operations to the input curves.