SimVT FAQ
How can I change the layout of the graphs?
By default the layout is set to 3x3, but you can change the layout from either the using graph options which can be accessed from both the Correlation Table window and the Plotting Controls window.
How can I invert the sign of my simulation or test curve so that they are consistent?
You can invert the sign of either curve using the "MULY" operation. Assuming the curves are in the same units you simply need to enter "-1" in the "MULY" column for the curve that needs corrected.
Why are the operations I have entered not being applied?
Operations that have not been applied yet will show with a turquoise background. They are only applied when the row is selected and plotted. In "Auto plot" mode, selecting a row is equivalent to plotting it so to force pending operations to be applied you simply need to select the row by pressing one of the object/location/channel/model buttons that corresponds to the row in question. When not in "Auto plot" mode you need to press the button to plot the selected row(s) and force the pending operations to be applied.
Why do the ratings say "NONE"?
The ratings will say none when it was not possible to perform the correlation. The main reason for this is that one or both of the curves do not lie within the min and max time window (a.k.a. evaluation interval) or there is a time offset between them such that they do not have points in the same X range. You should check the values of the "ADDX" and "MULY" operations to see if they could explain why the curves do not overlap.