PRIMER 22.1

Parameter Equal to Total Length

Parameter Equal to Total Length

This is optional. If defined it gives a parameter name (as defined by the *PARAMETER keyword) that will be updated with the total length of the as-meshed belt each time it is generated. This can be referred to elsewhere, typically in *ELEMENT_SEATBELT_SENSOR , to update attributes in accordance with the revised belt length. See Parameter to contain the total seatbelt length for more details.

Add _Sn parameter for each segment

As an extension to the above if this option is selected each segment of the belt will have its length assigned to a separate parameter, which can be used in any context.

To save having to define multiple names these parameters are given the name of the total length one above with "_s1", "_s2", etc added for segments #1, #2, etc. For example:

Nomenclature of per-segment parameters if parameter for total length is called BLEN
Segment 1 BLEN_S1
Segment 2 BLEN_S2
... etc for all belt segments.

Parameter names may not exceed 9 characters in normal Ansys LS-DYNA format, or 19 characters in long format. Therefore the name of the total length parameter will be truncated if necessary when adding " _S n " suffices in order to stay within these limits. For example if the total length parameter is " beltlen " then the parameter for segment #1 will be called " beltle_s1 " in normal format.

The following pairs of figures show alternative cases of no (seatbelt only) and 3 shell rows:

#rows =0: The seatbelt element only case #rows =3: Three shells across width